• 博客(0)
  • 资源 (13)

空空如也

鲁大师硬件检测

鲁大师是一款免费软件,并且不带任何插件和病毒。它适合下列操作系统: 操作系统:Windows2000/XP/2003/Vista/2008/7 官方网站:http://www.ludashi.com 简介: 鲁大师拥有专业而易用的硬件检测,不仅超级准确,而且向你提供中文厂商信息,让你的电脑配置一目了然,拒绝奸商蒙蔽。 它适合于各种品牌台式机、笔记本电脑、DIY兼容机,实时的关键性部件的监控预警,全面的电脑硬件信息,有效预防硬件故障,让您的电脑免受困扰。有硬件温度监测等带给你更稳定的电脑应用体验。

2011-09-21

N-TRON交换机

N-TRON的9000系列是一款具有千兆能力的全管理 型工业以太网交换机,它具备体积小巧,操作简便的特 点,非常适合应用于工业以太网或者工业安全设备的链接 产品特点

2011-09-21

Sixnet交换机

General Information Overview The EK Series is a line of industrial Ethernet switches designed to be rack or wall mounted. Up to 32 Ethernet ports are offered including 8 Gigabit ports, 8 PoE ports and up to 20 fiber optic ports. The rugged and compact 1U packaging allows them to fit into standard EIA, WECO and ETSI racks from 19 to 24”. This manual will help you install and maintain these industrial Ethernet switches. Installation of these switches is very easy and they will begin to operate as soon as they are powered up. Though these are fully managed switches, they will act as unmanaged until they are configured otherwise. Refer to the separate managed switch software manual for configuration of the advanced networking functionality and security.

2011-09-21

C200HX_HG_HE编程手册(中文)

CP1H简易Modbus/RTU控制 实验时间:2010年05月19日 实验人员:陶晓晨 实验器材:硬件:CP1H-XA40DR-D、3G3MV、CP1W-CIF11、S82J-02524D 软件:CX-Programmer 实验目的:1. 通过CP1H的RS-485口控制3G3MV变频器。 实验内容:1.实验要求:通过CP1H的RS-485串口,直接控制3G3MV变频器输出频率、启动、停止或者读取变频器频率等参数。 2.实验步骤 (1)硬件开关设定: CP1W-CIF11:工作设定用拨动开关中1,2,3,5,6号引脚置ON,4号引脚置OFF。 (2)PLC与3G3MV之间的接线: CP1H-XA40DR-D 3G3MV RDA-────── S-和R-短接 RDB+────── S+和R+短接 值得注意的是,由于PLC是直流供电的,不可直接接220V交流电,否则PLC将烧毁。所以将PLC的输入端接在服务电源上。 (3)变频器相关设定:( 变频器断电上电后,设置方可生效) SW2终端电阻拨到ON,n003=2,n004=6,n151=4,n152=0,n153=1,n154=2 n155=0,n156=10,n157=0 PLC的设置:(通过CX-P软件) 通过CX-P软件与PLC连接后,打开设置,将PLC的串口1设置如下:图1-1

2011-09-20

C200HX_HG_HE 编程手册

CP1H简易Modbus/RTU控制 实验时间:2010年05月19日 实验人员:陶晓晨 实验器材:硬件:CP1H-XA40DR-D、3G3MV、CP1W-CIF11、S82J-02524D 软件:CX-Programmer 实验目的:1. 通过CP1H的RS-485口控制3G3MV变频器。 实验内容:1.实验要求:通过CP1H的RS-485串口,直接控制3G3MV变频器输出频率、启动、停止或者读取变频器频率等参数。 2.实验步骤 (1)硬件开关设定: CP1W-CIF11:工作设定用拨动开关中1,2,3,5,6号引脚置ON,4号引脚置OFF。 (2)PLC与3G3MV之间的接线: CP1H-XA40DR-D 3G3MV RDA-────── S-和R-短接 RDB+────── S+和R+短接 值得注意的是,由于PLC是直流供电的,不可直接接220V交流电,否则PLC将烧毁。所以将PLC的输入端接在服务电源上。 (3)变频器相关设定:( 变频器断电上电后,设置方可生效) SW2终端电阻拨到ON,n003=2,n004=6,n151=4,n152=0,n153=1,n154=2 n155=0,n156=10,n157=0 PLC的设置:(通过CX-P软件) 通过CX-P软件与PLC连接后,打开设置,将PLC的串口1设置如下:图1-1

2011-09-20

HG_HE 编程手册(中文)

HG_HE 编程手册(中文) CP1H简易Modbus/RTU控制 实验时间:2010年05月19日 实验人员:陶晓晨 实验器材:硬件:CP1H-XA40DR-D、3G3MV、CP1W-CIF11、S82J-02524D 软件:CX-Programmer 实验目的:1. 通过CP1H的RS-485口控制3G3MV变频器。 实验内容:1.实验要求:通过CP1H的RS-485串口,直接控制3G3MV变频器输出频率、启动、停止或者读取变频器频率等参数。 2.实验步骤 (1)硬件开关设定: CP1W-CIF11:工作设定用拨动开关中1,2,3,5,6号引脚置ON,4号引脚置OFF。 (2)PLC与3G3MV之间的接线: CP1H-XA40DR-D 3G3MV RDA-────── S-和R-短接 RDB+────── S+和R+短接 值得注意的是,由于PLC是直流供电的,不可直接接220V交流电,否则PLC将烧毁。所以将PLC的输入端接在服务电源上。 (3)变频器相关设定:( 变频器断电上电后,设置方可生效) SW2终端电阻拨到ON,n003=2,n004=6,n151=4,n152=0,n153=1,n154=2 n155=0,n156=10,n157=0 PLC的设置:(通过CX-P软件) 通过CX-P软件与PLC连接后,打开设置,将PLC的串口1设置如下:图1-1

2011-09-20

C200HX_HG_HE 编程手册(中文)[

CP1H简易Modbus/RTU控制 实验时间:2010年05月19日 实验人员:陶晓晨 实验器材:硬件:CP1H-XA40DR-D、3G3MV、CP1W-CIF11、S82J-02524D 软件:CX-Programmer 实验目的:1. 通过CP1H的RS-485口控制3G3MV变频器。 实验内容:1.实验要求:通过CP1H的RS-485串口,直接控制3G3MV变频器输出频率、启动、停止或者读取变频器频率等参数。 2.实验步骤 (1)硬件开关设定: CP1W-CIF11:工作设定用拨动开关中1,2,3,5,6号引脚置ON,4号引脚置OFF。 (2)PLC与3G3MV之间的接线: CP1H-XA40DR-D 3G3MV RDA-────── S-和R-短接 RDB+────── S+和R+短接 值得注意的是,由于PLC是直流供电的,不可直接接220V交流电,否则PLC将烧毁。所以将PLC的输入端接在服务电源上。 (3)变频器相关设定:( 变频器断电上电后,设置方可生效) SW2终端电阻拨到ON,n003=2,n004=6,n151=4,n152=0,n153=1,n154=2 n155=0,n156=10,n157=0 PLC的设置:(通过CX-P软件) 通过CX-P软件与PLC连接后,打开设置,将PLC的串口1设置如下:图1-1

2011-09-20

Proficy Change management PPT

Why use Change Management? Increase Plant Up-Time and fast recovery from disasters Make sure backups are available when needed Reduce or prevent user errors Meet Regulatory Requirements (FDA/EPA) Provides required Electronic Records, Electronic Signatures, Audit Trails, Record Security and 21 CFR Part 11 for Life Sciences. Prevents Unauthorized access and use Improve Safety Eliminates errors that could cause injury or fatality Detects and Alerts for any changes

2011-09-20

Proficy Change Mangement

Proficy Change Management is part of GE Fanuc Automation’s Proficy Software Suite. Proficy Change Management provides asset management of your intellectual assets, those assets being the PLC programs and related files that are used to control your plant. Proficy Change Management can handle any file or set of files from any application. It stores those files on a secure server, meaning that you have up-to-date backups for all your applications. Proficy Change Management then prevents unauthorised access to those backups and maintains an audit trail so you can see who did what, where and when. This presentation provides an example of an interaction with a pre-engineered Proficy Change Management system.

2011-09-20

GE CHANGE MANAGEMENT

Congratulations on your purchase of Proficy Change Management, the most powerful and flexible automation system management tool available today. With Proficy Change Management, you can protect and coordinate all your projects throughout your system’s life cycle. Version control, centralized storage, security, automatic backups and more—they’re all covered. Proficy Change Management provides the following key features. ■ Centralized Storage & Version Control: tracks projects and safely stores previous versions. This ensures that everyone uses the correct files and databases, and virtually eliminates lost work. ■ Access Control: allows only users with approved security to access or modify projects. ■ Audit Trailing: tracks details of who did what, when they did it, and why. ■ Scheduler: enables the automatic completion of repetitive tasks such as backups and compares, saving you valuable time. ■ GE Fanuc Proficy Software support: Proficy Change Management is integrated with other Proficy software to provide a comprehensive solution, including Machine Edition, CIMPLICITY, and iFIX. ■ Third-party project support: Proficy Change Management is preconfigured to manage a variety of popular automation products from Rockwell, Siemens, Schneider and others, including Modicon ProWORX, Logicmaster 90-30 and 90-70, and GE Fanuc CNC. ■ Factory Layouts: allows you to organize your projects to better fit your company’s structure, making it easier for users to navigate to a project. ■ Reporting Tools: allows you to generate detailed reports of audit trails. ■ Electronic Signatures: designed with the regulated companies in mind, electronic signatrures provide an extra level of control by requiring signatures for changes made to projects.

2011-09-20

Proficy Histrian

出类拔萃的企业级历史数据采集平台 生产信息是现代企业生产正常运转的根源。随着产品生产复杂度不 断地增加,要有效地管理庞大的操作数据并把这些数据转变为有用 的信息变得越来越困难。 寻找一个快捷、易用且具有成本效益的方式来采集、规格化并存 储生产数据始终是一个棘手的任务。并且利用这些生产信息对时 刻变化的新需求做出实时决策也不是一件简单的任务。Proficy Historian(原名 iHistorian)可以胜任数据管理的巨大挑战使您获得 最佳操作性能。 无论您是一家小型的设备工厂或一家全球性的制药企业,还是一所 具有关键性任务的航天机构,Proficy Historian 都能使您的企业取 得更大的利润和更强的生产力。Proficy Historian 是获得高效生产 管理的基石。 Proficy Historian 在要求最高的数据管理情况下表现得非常卓越。 它的使用和维护都很简易,速度和性能无与伦比,在最关键的应 用任务中表现得非常可靠,并且它的扩展性极佳—— 在如何管理 生产数据方面它是真正具有革命性的。 利用具有 Historian 数据管理能力的大量性能和执行应用,我们能 帮助您解决任何特定的生产需求。从机器停机报告和 OEE 到质量 和废料管理再到产品可跟踪性,Proficy 解决方案为您优化生产提 供了一个具有成本效益的有效方式。 出类拔萃的企业级历史数据采集平台

2011-09-20

ifix4.0入门

ifix入门 目 录 为什么要阅读该入门手册...................................................................................................................................... 1. 一般安装信息............................................................................................................................................................   设置总览 ....................................................................................................................................................................   硬件要求 ....................................................................................................................................................................    推荐的计算机.....................................................................................................................................................    内存需求 ...............................................................................................................................................................    磁盘空间要求.....................................................................................................................................................    硬件密钥 ...................................................................................................................................................................    安装硬件密钥.....................................................................................................................................................    授权和密钥检查 ................................................................................................................................................    排除硬件密钥的安装错误.............................................................................................................................    更换损坏的硬件密钥......................................................................................................................................    关于硬件密钥的一般问题 .........................................................

2011-09-20

空空如也

TA创建的收藏夹 TA关注的收藏夹

TA关注的人

提示
确定要删除当前文章?
取消 删除